Test plan:
1 - prove t/db_dependent/Barcodes.t
2 - All should pass
3 - Apply first patch (unit tests update)
4 - Tests should fail on values and warnings
5 - Apply second patch
6 - All tests should now pass
Signed-off-by: Bernardo Gonzalez Kriegel <bgkriegel@gmail.com>
Work as described
Removed tab on line 47 of C4/Barcodes/hbyymmincr.pm
No more qa errors
Signed-off-by: Jonathan Druart <jonathan.druart@bugs.koha-community.org>
Signed-off-by: Kyle M Hall <kyle@bywatersolutions.com>
This patch alters the MySQL query to remove a max statement which
incorrectly groups full annual barcodes with numeric values.
Signed-off-by: Srdjan <srdjan@catalyst.net.nz>
Signed-off-by: Jonathan Druart <jonathan.druart@bugs.koha-community.org>
Signed-off-by: Brendan Gallagher brendan@bywatersolutions.com
Mainly a
perl -p -i -e 's/^.*3.07.00.049.*\n//' **/*.pm
Then some adjustements
Signed-off-by: Josef Moravec <josef.moravec@gmail.com>
Signed-off-by: Tomas Cohen Arazi <tomascohen@unc.edu.ar>
Signed-off-by: Brendan A Gallagher <brendan@bywatersolutions.com>
perl -p -i -e 's/^(use vars .*)\$VERSION\s?(.*)/$1$2/' **/*.pm
Signed-off-by: Josef Moravec <josef.moravec@gmail.com>
Signed-off-by: Tomas Cohen Arazi <tomascohen@unc.edu.ar>
Signed-off-by: Brendan A Gallagher <brendan@bywatersolutions.com>
To test:
- Set autoBarcode = <branchcode>yymm0001
- Make sure you have a serial that is set to "create an item record
when receiving this serial"
- Receive an issue
- Click in the barcode field - nothing happens
- Apply patch and reload page
- Receive an issue
- Click in the barcode field - a barcode conforming to the
hbyymmincr setting appears
Patch works as advertised.
Signed-off-by: Marc Véron <veron@veron.ch>
Signed-off-by: Jonathan Druart <jonathan.druart@bugs.koha-community.org>
Signed-off-by: Tomas Cohen Arazi <tomascohen@theke.io>
Test plan: See Bugzilla.
Signed-off-by: Jonathan Druart <jonathan.druart@biblibre.com>
Signed-off-by: Marcel de Rooy <m.de.rooy@rijksmuseum.nl>
Signed-off-by: Tomas Cohen Arazi <tomascohen@unc.edu.ar>
When AutoBarcode is activated and you have set AcqCreateItem to 'on
order' there is a Javascript error when you try to generate a barcode
for the item:
TypeError: document.f is undefined
http://localhost:8080/intranet-tmpl/lib/jquery/jquery.js
Line 11
Test plan:
0/ a. Set AutoBarcode to hbyymmincr
b. Set AcqCreateItem to 'on ordering'
c. Set the plugin barcode.pl to the barcode field for the default
and the ACQ frameworks
1/ Go on the add items page (cataloguing/additem.pl) and confirm that
the plugin works as expected.
2/ Go on the New order page (acqui/neworderempty.pl) and confirm that
the plugin works as expected.
Followed test plan, works as expected.
Signed-off-by: Marc Véron <veron@veron.ch>
Signed-off-by: Katrin Fischer <katrin.fischer.83@web.de>
Signed-off-by: Tomas Cohen Arazi <tomascohen@theke.io>
Most of them were found and fixed using codespell.
Fix also some related grammar issues.
In C4/Serials.pm a variable was renamed to make future codespelling
checks easier.
Signed-off-by: Stefan Weil <sw@weilnetz.de>
http://bugs.koha-community.org/show_bug.cgi?id=14383
Signed-off-by: Bernardo Gonzalez Kriegel <bgkriegel@gmail.com>
Signed-off-by: Jonathan Druart <jonathan.druart@koha-community.org>
Signed-off-by: Tomas Cohen Arazi <tomascohen@theke.io>
Signed-off-by: Chris Nighswonger <cnighswonger@foundations.edu>
Signed-off-by: Tomas Cohen Arazi <tomascohen@gmail.com>
Signed-off-by: Katrin Fischer <katrin.fischer@bsz-bw.de>
http://bugs.koha-community.org/show_bug.cgi?id=9987
Signed-off-by: Kyle M Hall <kyle@bywatersolutions.com>
Signed-off-by: Tomas Cohen Arazi <tomascohen@gmail.com>
The hbyymmincr autoBarcode builder looks up all barcodes that begin with
any number of letters ( the branchcode ) and a two-digit year directly
afterward ( e.g. MPL15 ), then grabs the last four digits as the
increment counter. The problem is, this does not take months into
account, so unlike the description that says the system is limited to
10,000 items a month, it is limited to 10,000 items per *year*.
This situation can easily be corrected my adding the month into the
lookup ( e.g. MPL1501 ).
Test Plan:
1) Enable autoBarcode, set to hbyymmincr
2) Catalog an item, let the barcode.pl plugin generate
the next barcode.
3) Catalog an item with the barcode MPL15009999
4) Catalog another item, use the barcode.pl plugin to
generate the next barcode.
5) Note the barcode is generated ends with '0001' instead of the
correct increment
6) Apply this patch
7) Repeat step 4
8) Note the barcode now ends with the correct increment
Signed-off-by: Kyle M Hall <kyle@bywatersolutions.com>
Signed-off-by: Jeanne Heicher <nppublib@pa.net>
Signed-off-by: Katrin Fischer <katrin.fischer.83@web.de>
Problem confirmed - the continuing number bit was not reset
to start counting from 1 again on the beginning of a new month.
Signed-off-by: Tomas Cohen Arazi <tomascohen@gmail.com>
This patch removes C4::Barcodes::PrinterConfig, which is
used by no other code in the database.
Signed-off-by: Emma Heath <emmaheath.student@wegc.school.nz>
Signed-off-by: Kyle M Hall <kyle@bywatersolutions.com>
No instances of PrinterConfig found in the codebase
Signed-off-by: Katrin Fischer <Katrin.Fischer.83@web.de>
Couldn't find any reference to those files in Koha.
Signed-off-by: Galen Charlton <gmc@esilibrary.com>
- Subroutine prototypes used at line 45, column 1. See page 194 of PBP. (Severity: 5)
Signed-off-by: Jonathan Druart <jonathan.druart@biblibre.com>
Signed-off-by: Paul Poulain <paul.poulain@biblibre.com>
In addition to adding a new barcode plugin, this commit begins
refactoring the barcode generation code using a new module,
C4::Barcodes::ValueBuilder. From the POD:
This module is intended as a shim to ease the eventual transition
from having all barcode-related code in the value builder plugin
barcode.pl file to using C4::Barcodes. Since the shift will require
a rather significant amount of refactoring, this module will return
value builder-formatted results, at first by merely running the
code that was formerly in the barcodes.pl value builder, but later
by using C4::Barcodes.
Signed-off-by: Kyle M Hall <kyle@bywatersolutions.com>
Implement auto-incrementing EAN-13 barcodes
To make this work, C4::Barcodes::next was modified to call process_tail with
new incremented value so that process_tail can generate correct checksum.
Since process_tail is currenlty not used by any barcodes, this change is safe.
C4::Barcodes is used by addbiblio.pl when adding multiple records, while value_builder
is used in all other cases.
Test scenario:
1. prove t/Barcodes_EAN13.t
2. KOHA_CONF=/etc/koha/sites/fer/koha-conf.xml prove t/db_dependent/Barcodes.t
this will check C4::Barcode implementataion
3. in systempreference change autoBarcode to incremental EAN-13 barcode
4. edit two items of any biblio assigning barcodes and verify that numbers
are increasing. Have in mind that last digit is check digit, and it
doesn't increment, but is calculated from barcode itself. Example with
checksum in brackets: 000000086275[2], 000000086276[9], 000000086277[6]
5. Add Item and verify that it gets assigned next barcode
6. Add & Duplicate item and verify barcode increase
7. Add Multiple Copies and verify that barcode increase for each copy
Signed-off-by: Chris Cormack <chris@bigballofwax.co.nz>
Signed-off-by: Paul Poulain <paul.poulain@biblibre.com>
working through the master branch to eliminate all
podchecker warnings/errors
Actual improvement to the quality of the POD will
come later (hopefully with assistance of others)
Signed-off-by: Andrew Elwell <Andrew.Elwell@gmail.com>
Signed-off-by: Galen Charlton <gmcharlt@gmail.com>
Signed-off-by: Chris Cormack <chrisc@catalyst.net.nz>
Following suggestion by Vincent Danjean for Debian
packaging, 0755 -> 0644 for non-executable
files.
Also removed shebang from a few modules in C4.
Signed-off-by: Galen Charlton <galen.charlton@liblime.com>
This code is intended to replace current value_builder code in 3.2, but
it does not affect it directly (yet) and is safe to include in 3.0.
This structure will be used to handle more complicated formats, like those
with checkdigits. Please note that "incremental" format is still STRONGLY
recommended because it will always perform the best, and most flexibly.
The desire to include other information (like branchcode) should compel
the proper use of the barcode generator to print the info ON the barcode,
not IN the barcode.
One of the nicer features of this structure is that you are able to
create a new barcode (of the same type) based on any previous Barcodes object.
That means you can create an array of 51 consecutive barcodes like:
my $x = C4::Barcodes->new('annual'); # for example
my @set = ($x);
for (1..50) {
push @set, $x=$x->new;
}
Importantly, this can happen without referencing the database after the
first constructor.
Signed-off-by: Joshua Ferraro <jmf@liblime.com>
Uses a complete new ZEBRA Indexing.
ZEBRA is now XML and comprises of a KOHA meta record. Explanatory notes will be on koha-devel
Fixes UTF8 problems
Fixes bug with authorities
SQL database major changes.
Separate biblioograaphic and holdings records. Biblioitems table depreceated
etc. etc.
Wait for explanatory document on koha-devel