When XSLT is enabled, the subject tracings on the details view (both OPAC and
Intranet) previously only searched on the subfield 'a'. In addition, searches
failed when the tracing included parentheses, and the XSLT display did not
include subfields other than abcdvxyz, even for those 6xx tags that have other
subfields.
This patch adds a syspref: TraceSubjectSubdivisons. When
TraceSubjectSubdivisions is set to "Don't include" (default), the subject
tracings in the XSLT details view will only search on subfield 'a'. When
TraceSubjectSubdivisions is set to "Include", the subject tracings will search
on all subfields, not just subfield 'a'.
Signed-off-by: Nicole C. Engard <nengard@bywatersolutions.com>
Signed-off-by: Chris Cormack <chrisc@catalyst.net.nz>
On OPAC/staff result page facets are truncated to 20 characters. On some OPAC
layout, it's not enough. A new syspref FacetLabelTruncationLength defines the
length to cut facets if necessary.
This patch add the syspref to searching.pref and add it to syspref various
language default values loaded into DB during installation process. It's not
necessary to update DB since length is fixed to 20 (as before) when this
syspref isn't defined in systemprefercences table.
Rebased to last HEAD: 2011.03.18
[Documentation] FacetLabelTruncationLength syspref in Searching tab
[3.2] It doesn't apply.
Signed-off-by: Nicole C. Engard <nengard@bywatersolutions.com>
Signed-off-by: Chris Cormack <chrisc@catalyst.net.nz>
Based on patch from Fridolyn Somers with input of Frederic Demians.
Added new Searching preference maxRecordsForFacets.
This pref contains number of result records used in facet building.
Also added pref displayFacetCount (with thanks to Frederic).
Follow up patch takes care of install issues; functionality can already be tested with this patch only.
Updated on March 17 for changes in include files.
Signed-off-by: Nicole C. Engard <nengard@bywatersolutions.com>
Signed-off-by: Chris Cormack <chrisc@catalyst.net.nz>
This patch adds the syspref TraceCompleteSubfields. When TraceCompleteSubfields
is set to "force," clicking on links in non-authority controlled subject
tracings will only find other records where the entire subfields match. Leaving
it at "don't force" keeps the current behavior of doing a keyword search of the
subject indexes.
This patch implements complete-subfield subject tracings in MARC21 XSLTs (OPAC
and Staff) and all Normal mode interfaces. UNIMARC XSLTs have not been updated.
This patch also adds the syspref UseAuthoritiesForTracings. When set to "Do not"
tracings in the XSLT detail displays will never generate links using authority
numbers, but rather use the heading strings (NB: the tracings currently use only
subfield 'a' for generating links).
Signed-off-by: Nicole C. Engard <nengard@bywatersolutions.com>
Signed-off-by: Jane Wagner <jwagner@ptfs.com>
Signed-off-by: Jared Camins-Esakov <jcamins@bywatersolutions.com>
Signed-off-by: Chris Cormack <chrisc@catalyst.net.nz>
Reinstates the deleted maxItemsInSearchResults system preference, which was erroneously thought to no longer be utilized.
It's removal has led to bug 4430
Signed-off-by: Nicole Engard <nengard@bywatersolutions.com>
Signed-off-by: Chris Cormack <chrisc@catalyst.net.nz>
Syspref .pref file was defining a code for descending order which wasn't
expected by .tmpl files... 'desc' instead of 'dsc'.
Signed-off-by: Galen Charlton <gmcharlt@gmail.com>
Signed-off-by: Chris Cormack <chrisc@catalyst.net.nz>
- Add two syspref:
- OPACXSLTResultsDisplay
- OPACXSLDetailsDispay
- Add them to .pref files and dispatch them beetween OPAC and Search
tab.
- Upgrade DB version to 3.2 .113
- Fix something wrong in UNIMARCslim2intranetDetail.xsl
- Display OPAC result and detail pages using those syspref.
Signed-off-by: Galen Charlton <gmcharlt@gmail.com>