Commit graph

9 commits

Author SHA1 Message Date
Agustin Moyano
52deed335e Bug 23816: (follow-up) Fix many things
This patch:
 * reverts changes on misc/admin/set_password.pl
 * makes category param mandatory for AuthUtils::is_valid_password and AuthUtils::generate_password
 * changes onboarding.pl to set category param in AuthUtils::is_valid_password
 * Completes t/db_dependent/AuthUtils.t and drops t/AuthUtils.t
 * Removes offending <input type="number"/> and replaces it by <input type="text" inputmode="numeric" pattern="[0-9]*"/>

https://bugs.koha-community.org/show_bug.cgi?id=23826

Signed-off-by: Katrin Fischer <katrin.fischer.83@web.de>
Signed-off-by: Tomas Cohen Arazi <tomascohen@theke.io>

Signed-off-by: Jonathan Druart <jonathan.druart@bugs.koha-community.org>
2020-09-09 15:39:52 +02:00
Agustin Moyano
5848da810e Bug 23816: Add minimum password length and require strong password overrides by category
This patch adds the capability to override minPasswordLenth and RequireStrongPassword settings by category

To test:
1. koha-shell kohadev
2. koha-mysql kohadev

3. drop database koha_kohadev;
4. create database koha_kohadev;

5. go to admin page and start webinstaller. There continue the steps until onboarding.
6. reach step 3 of onboarding and create a new administrator patron
CHECH => Password control woks as normal (Minimum length 3 and strong required)

7. finish Koha installation and enter admin with your new administrator
8. set minPasswordLength to 3 and RequireStrongPassword to “Don’t require”
9. Create a new category (CAT2 from now on.. CAT1 is the category you made in onboarding process) and set minimum password length to 8 and require strong password
10. Create two new patrons, one with CAT1(patron1) and one with CAT2 (patron2)
CHECK => In both cases, try different combinations of length and strength. For patron1 the only requirement is to have 3 letters, but for patron2 the minimum length will be 8 and will require strong password.
CHECK => Try changing patron category before saving. Password requirements will change with category change.

11. Edit CAT1 and set minimum password length to 5
12. Go to patron1 details page, and change password.
CHECH => Now password minimum length is 5, but still it doesn’t require strong password

13. Edit CAT1, leave blank minimum password length and set require strong password to yes.
14. Go to patron1 details page, and change password.
CHECH => Password minimum length is back to 3, but now strong password is required

15. Set minimum password length in CAT2 to 12.
16. Go to patron2 details page, and click to fill a random generated password
CHECK => generated password should be 12 characters length

17. Set PatronSelfRegistration to Allow in admin settings
18. Go to OPAC and fill self registration from.
CHECK => Play with patron category. For each change in category, password requirements are modified.
CHECK => Set CAT1 as patron category, set ‘aA1’ as password (or another valid password for CAT1) and before hitting submit button, change to CAT2. Form should enter invalid state, and CAT2 password requirements should be displayed as error in password input.

19. Create a patron for CAT1 and another for CAT2, leaving password blank
CHECK => For CAT1’s patron, generated password length is 8 (minimum length for generated passwords), but for CAT2’s patron should be 12

20. In admin set PatronSelfRegistrationVerifyByEmail to require
21. Fill self registration form again with CAT2 as category
CHECK => Password requirements works as previous case.
22. Leave password blank and click submit

23. select * from message_queue;
24. Copy the link in the message and paste it in OPAC
CHECH => Generated password is 12 characters long. (Copy user id for next steps)

25. In admin set OpacResetPassword to Allow
26. Go back to OPAC, reload and click on “Forgot password?” link
27. Paste user id and click submit
28. Repeat steps 23 and 24
CHECK => Info message says “Your password must contain at least 12 characters, including UPPERCASE, lowercase and numbers.”
CHECK => enter an invalid password and you’ll get the same message in warning.

29. Login OPAC with the last user and your newly created password
30. Go to “Change your password” option
CHECK => Info message says “Your password must contain at least 12 characters, including UPPERCASE, lowercase and numbers.”
CHECK => enter an invalid password and you’ll get the same message in below “New password” input.

31. prove t/db_dependent/AuthUtils.t t/db_dependent/Koha/Patron/Category.t

32. Sign off

Sponsored-by: Northeast Kansas Library - NEKLS

Signed-off-by: Andrew Fuerste-Henry <andrew@bywatersolutions.com>

Signed-off-by: Katrin Fischer <katrin.fischer.83@web.de>
Signed-off-by: Tomas Cohen Arazi <tomascohen@theke.io>

Signed-off-by: Jonathan Druart <jonathan.druart@bugs.koha-community.org>
2020-09-09 15:39:52 +02:00
David Roberts
81c141d41a
Bug 20370: Misleading comment for bcrypt - #encrypt it; Instead it should be #hash it
This patch changes the wording of the comment

To test:

1) Check the wording of Line 67 of Koha/AuthUtils.pm
2) Apply the patch
3) Check that the wording has changed from "Encrypt it" to "Hash it"

Signed-off-by: Katrin Fischer <katrin.fischer.83@web.de>
Signed-off-by: Martin Renvoize <martin.renvoize@ptfs-europe.com>
2020-04-14 08:35:24 +01:00
543630b3c4 Bug 21719: Fix typos
This patch was generated using codespell

Test plan:
Read through changes and confirm they make sense

Signed-off-by: Josef Moravec <josef.moravec@gmail.com>

Signed-off-by: Owen Leonard <oleonard@myacpl.org>

Signed-off-by: Katrin Fischer <katrin.fischer.83@web.de>

https://bugs.koha-community.org/show_bug.cgi?id=21706

Signed-off-by: Nick Clemens <nick@bywatersolutions.com>
2018-11-08 02:18:46 +00:00
3f9da34683 Bug 18298: Add server-side checks and refactor stuffs
Now that we have a check client-side, nothing prevents us from a smart guy to
bypass it and force an invalid password.
This patch adds two new subroutines to Koha::AuthUtils to check the
validity of passwords and generate a password server-side. It is used
only once (self-registration) but could be useful later.

Moreover the 3 different cases of password rejection (too leak, too
short, contains leading or trailing whitespaces) were not tested
everywhere. Now they are!

This patch makes things consistent everywhere and clean up some code.

Signed-off-by: Marc Véron <veron@veron.ch>
Signed-off-by: Tomas Cohen Arazi <tomascohen@theke.io>

Signed-off-by: Jonathan Druart <jonathan.druart@bugs.koha-community.org>
2017-10-16 09:44:32 -03:00
Jesse Weaver
d475dae773 Bug 16818: External auth redirect broken under Plack
Test plan:

0) Have either CAS or Shibboleth authentication enabled under Plack.
1) Hover over the authentication link on the staff client or OPAC, and
   notice that it has either '.../opac/...' or '.../intranet/...' instead
   of '.../cgi-bin/koha/...'. (This will be a complete dealbreaker for CAS
   authentication.)
2) Apply patch.
3) Check links again; they should now have the correct paths.

Signed-off-by: Matthias Meusburger <matthias.meusburger@biblibre.com>

Signed-off-by: Jonathan Druart <jonathan.druart@bugs.koha-community.org>
Did not test CAS or Shibboleth, but no regression found.

Signed-off-by: Brendan Gallagher <brendan@bywatersolutions.com>
2016-08-04 19:42:44 +00:00
017699c345 Bug 16011: $VERSION - Remove the $VERSION init
Mainly a
  perl -p -i -e 's/^.*3.07.00.049.*\n//' **/*.pm
Then some adjustements

Signed-off-by: Josef Moravec <josef.moravec@gmail.com>
Signed-off-by: Tomas Cohen Arazi <tomascohen@unc.edu.ar>

Signed-off-by: Brendan A Gallagher <brendan@bywatersolutions.com>
2016-03-24 17:20:28 +00:00
Jonathan Druart
fe1e6d86ca Bug 11944: Authentication
The password should be encoded before hashing.

Test plan:
- Before applying the patch, create a user with utf-8 in password
- apply patches
- try to log in
- change the password
- log out
- try to log in

Signed-off-by: Paola Rossi <paola.rossi@cineca.it>
Signed-off-by: Bernardo Gonzalez Kriegel <bgkriegel@gmail.com>
Signed-off-by: Dobrica Pavlinusic <dpavlin@rot13.org>

Signed-off-by: Martin Renvoize <martin.renvoize@ptfs-europe.com>
Signed-off-by: Tomas Cohen Arazi <tomascohen@gmail.com>
2015-01-13 13:07:14 -03:00
Galen Charlton
547c6d2949 Bug 9611: (follow-up) move new password hashing routines to separate module
The move avoids a problem where many modules would gain
a dependency on C4::Auth just because C4::Members needs access
to hash_password().

This patch also adds a couple unit tests for the new password
hashing code.

To test:

[1] Verify that there are no regressions on the test plan for bug
    9611.
[2] Verify that t/AuthUtils.t and t/db_dependent/Auth.t pass.

Signed-off-by: Galen Charlton <gmc@esilibrary.com>
2013-10-09 03:29:22 +00:00