Adding Type of Unit (300$f) to the Opac details and staff side searches results and details display
Signed-off-by: Claire Gravely <claire.gravely@bsz-bw.de>
Signed-off-by: Katrin Fischer <katrin.fischer.83@web.de>
Signed-off-by: Nick Clemens <nick@bywatersolutions.com>
Adding 245$f and 245$g to the Results and Detail pages on OPAC and staff side
Signed-off-by: Joy Nelson <joy@bywatersolutions.com>
Signed-off-by: Cab Vinton <bibliwho@gmail.com>
Signed-off-by: Josef Moravec <josef.moravec@gmail.com>
Signed-off-by: Nick Clemens <nick@bywatersolutions.com>
Test plan:
1. Open a list of results
2. Use fn+f12 to inspect element
3. Without patch it should show that the image class is 'materialtype'
4. With patch there will be an additional class
-Books = mt_icon_BK
-Kit = mt_icon_MX
-Article = mt_icon_AR
-Continuous resource = mt_icon_CR
-Mixed material = mt_icon_MX
-Computer files = mt_icon_CF
-Map = mt_icon_MP
-Music = mt_icon_MU
-Sound = mt_icon_MU
-Score = mt_icon_PR
-Visual material = mt_icon_VM
OR
1. Try using the classes in css to change the style
-When viewing the details of a record, the material type img should also have the
same changes
-Check that the material type classes in the results page is the same as
the details page
Signed-off-by: Owen Leonard <oleonard@myacpl.org>
Signed-off-by: Katrin Fischer <katrin.fischer.83@web.de>
I've squashed the patches to make chanes easier readable.
Signed-off-by: Nick Clemens <nick@bywatersolutions.com>
The code to show the ISBN and ISSN is repeated between the search results
and the detail view. Create a function to show the ISBN/ISSN, and call
that instead.
Test plan:
1) Apply patch
2) Search for any records, check that the ISBN and ISSN are shown
correctly
3) Go to biblio detail pages, check that the ISBN and ISSN are shown
correctly
Signed-off-by: Pasi Kallinen <pasi.kallinen@joensuu.fi>
Signed-off-by: claude <claude.brayer@cea.fr>
Signed-off-by: Martin Renvoize <martin.renvoize@ptfs-europe.com>
Signed-off-by: Nick Clemens <nick@bywatersolutions.com>
I added a magnigying glass icon in the staff detail view that links to
the authority records.
Test Plan:
1) On the Koha staff page, create a new authority. The type of authority
will be: Topical Term.
2) When creating authority, in tab 1 under -HEADING--TOPICAL TERM enter
the topical term or geographic name entry element and then save the
new authority e.g. science.
3) In circulation, search the catalog for a random book. Click the title
of the book and you will be taken to the book details.
4) Edit the record and in tab 6, scroll down the - SUBJECT ADDED
ENTRY--TOPICAL TERM and repeat this tag (the icon next to the title).
5) Edit the Topical term or geographic name entry element by clicking
the button on the right of the bar.
6) In the Search main heading ($a only) enter your topical term e.g.
science.
7) Press search, and then in the table that pops up, click 'choose'.
8) Save your edits and the new topical term will be in the 'Subject(s)'
list of the book details.
9) Notice that there is no magnifying glass icon.
10) Apply this patch
11) Notice that there is now a magnifying glass icon next to the topical
term.
12) Click on the magnifying glass and it will take you directly to the
authorities records
Signed-off-by: Owen Leonard <oleonard@myacpl.org>
Signed-off-by: Katrin Fischer <katrin.fischer.83@web.de>
Signed-off-by: Jonathan Druart <jonathan.druart@bugs.koha-community.org>
Zebra doesn't care about cases, but ES does and default mapping is
'control-number'
Signed-off-by: Nick Clemens <nick@bywatersolutions.com>
Signed-off-by: Jonathan Druart <jonathan.druart@bugs.koha-community.org>
See MARC specification.
Note that we have a preceding text before all 776s too.
Test plan:
[1] Set field 776 ind2 to 8. And add text in $i.
[2] Look for this text on OPAC detail and staff detail.
Signed-off-by: Marcel de Rooy <m.de.rooy@rijksmuseum.nl>
Signed-off-by: Felix Hemme <felix.hemme@thulb.uni-jena.de>
Signed-off-by: Nick Clemens <nick@bywatersolutions.com>
Signed-off-by: Jonathan Druart <jonathan.druart@bugs.koha-community.org>
Adds code to opac and staff detail XSLT in order to show 776$t (or $a) and
a link based on 776$w (record control number). $w should be in the form:
(MARCOrgCode)Record-number
For instance: (NL-AmRIJ)12345
Note: You should have enabled default opac/intranet XSLT view.
Test plan:
[1] Add two 776s (one with $t and $w and one with $t only)
[2] Verify that you see "Additional physical formats" on opac-detail. Does
the link for $w work?
[3] Check intranet detail too.
[4] Empty 776$t and put text in $a. Check detail page again.
Signed-off-by: Marcel de Rooy <m.de.rooy@rijksmuseum.nl>
Signed-off-by: Felix Hemme <felix.hemme@thulb.uni-jena.de>
Signed-off-by: Nick Clemens <nick@bywatersolutions.com>
Signed-off-by: Jonathan Druart <jonathan.druart@bugs.koha-community.org>
Signed-off-by: Mirko Tietgen <mirko@abunchofthings.net>
Signed-off-by: Nick Clemens <nick@bywatersolutions.com>
Signed-off-by: Kyle M Hall <kyle@bywatersolutions.com>
Test Plan
1: Add something inside c and h of 245 on a Bibliographic Record. There won't be a space between
the c and h
2: This will occur on both the search results and the details pages of
the record in both the intranet and opac.
3: Apply the patch
4: Refresh and see that there is now a space between c and h.
Signed-off-by: Katrin Fischer <katrin.fischer.83@web.de>
Signed-off-by: Kyle M Hall <kyle@bywatersolutions.com>
test plan
Edit a record
Edit field 583a to add an action note
Save the record and confirm that the note does not show up in staff
client or opac
Apply patch and refresh page
Action note should now show up in staff client and opac
Signed-off-by: Katrin Fischer <katrin.fischer.83@web.de>
Signed-off-by: Kyle M Hall <kyle@bywatersolutions.com>
This patch respect previous css classes
.authordates and .relatorcode but also include .titleportion
.authordates {display: none;}
.titleportion {display: none;}
.relatorcode {display: none;}
To test:
- Stage the two record attached with titles:
- Surface & coatings technology.
- Women crime writers.
- Reindex zebra (necessary to Opac and Itranet results)
- Leave empty the OPACUserCSS and IntranetUserCSS sysprefs
- Go to the new records in OPAC and Intranet detail page
- See the wrong display of dates
- Apply patch and refresh the page
- Test in OPACUserCSS and IntranetUserCSS the css stated before
- Play deleting or adding the classes
- Test with multiple records with 700 (with and without dates, etc;
710 and 711)
NOTE: dates in 710 and 711 can be hidden with .titleportion class;
dates in this kind of heading go with another data for example:
Catholic Church. Plenary Council of Baltimore (2nd : 1866)
Patch rebased some typos fixed in comments
Signed-off-by: Dani Elder <danielle@bywatersolutions.com>
Signed-off-by: Katrin Fischer <katrin.fischer.83@web.de>
Signed-off-by: Kyle M Hall <kyle@bywatersolutions.com>
Includes class="suppressed_opac" for library specific styles.
Suggested css: .suppressed_opac { color:red; font-size:1.25em; font-weight:bold; float:right; margin-right:2em; clear:none; }
Signed-off-by: Nick Clemens <nick@quecheelibrary.org>
Signed-off-by: Kyle M Hall <kyle@bywatersolutions.com>
Signed-off-by: Katrin Fischer <katrin.fischer.83@web.de>
Signed-off-by: Marcel de Rooy <m.de.rooy@rijksmuseum.nl>
Signed-off-by: Kyle M Hall <kyle@bywatersolutions.com>
This patch add display link in XSLT for 264 for bug 14198 and reflect the
Zebra indexing 'Provider' in detail page for Intranet.
Test plan
1) Update zebra index if no Provider: index exist
2) Do a search by Provider:
3) Goto detail page for a record with 264
4) Look that there no display link for 264 field.
5) Apply the patch
6) Reload the page, notice about the link, click the link an confirm
the new index Provider works fine
7) Test with multiple records with 260 and 264, if you prefer follow test plan
for bug 14734
8) Access an RCAA2 record just with 260 field
9) Notice that 260 has been updated with Provider index too.
NOTE: The intention of Provider index -according with documentation- is
to collect multiples fields including 260, 264, 270, and 257
Sponsored-by: Universidad de El Salvador
Signed-off-by: Katrin Fischer <katrin.fischer.83@web.de>
Signed-off-by: Marcel de Rooy <m.de.rooy@rijksmuseum.nl>
Signed-off-by: Brendan Gallagher brendan@bywatersolutions.com
With the changes for RDA now more subfields for the fields
100, 110, 111, and 700, 710, 711 are displayed.
One of them is $d - Dates associated with a name
This patch adds separate treatment of the $d subfield and
wraps it in a span with the class "authordates".
This makes it possible to hide the information with CSS.
To test:
- Make sure you have several records with $d catalogued
- Check the display in result list and detail page
with and without the page.
- Check, if there is a difference in display
- Check if the dates are correctly wrapped in a span
- Try to hide the information, using the following
entry in your *UserCSS preferences:
.authordates { display: none; }
Signed-off-by: Hector Castro <hector.hecaxmmx@gmail.com>
Works as advertised
Signed-off-by: Jesse Weaver <jweaver@bywatersolutions.com>
Signed-off-by: Brendan A Gallagher <brendan@bywatersolutions.com>
This patch adds a separator for multiple 508 fields to the XSLT display in the staff and OPAC detail view.
Separator is wrapped in span with class=‘separator’ for easy manipulation via css.
To test:
* Search the OPAC
* Click the title with multiple 508 fields
* Make sure the fields display properly
* Repeat for a few more titles
* Repeat in the Staff Client
Signed-off-by: Mark Tompsett <mtompset@hotmail.com>
Signed-off-by: Katrin Fischer <katrin.fischer.83@web.de>
Signed-off-by: Brendan A Gallagher <brendan@bywatersolutions.com>
To test:
-Search records with 336, 337, 338, 700$i, and 7XXind=2
-Search records with 508, 264Ind=4, 246, 856, and LDR/6 and
LDR/7 (BK, VM, CR, CF)
-Notice the capitalization (Contained Works, Related Works, Media Type,
Content Type, and Carrier Type, Production Credits, Copyright Date,
Other Title, Online Access, Continuing Resource, Mixed Materials,
Computer File, Visual Material) in both OPAC and Intranet for
records detail pages and results pages
-Apply this patch
-Search again and get notice about the capitalization following
Koha coding guidelines
Signed-off-by: Frederic Demians <f.demians@tamil.fr>
Signed-off-by: Jonathan Druart <jonathan.druart@bugs.koha-community.org>
Signed-off-by: Tomas Cohen Arazi <tomascohen@theke.io>
Makes 264 repeatable, prefer 264 over 260. If 264/ind1=3 is present in the
record the xslt uses ind1 to determine latest 264, if no ind1=3 then all
264 fields are displayed.
Test Plan:
1) Apply this patch
2) Ensure you are using the default XSLT setting for the staff and opac record details
3) Find or create a record with multiple MARC tags 264
4) Perform a search that would show the record in the search results.
5) Review results for correct 264 display.
6) Click title to review record details.
Signed-off-by: Hector Castro <hector.hecaxmmx@gmail.com>
Works as advertised. 260 not showed when 264 exists, tested with multiple
records. If ind1=3 is present shows the current/latest data
Signed-off-by: Katrin Fischer <katrin.fischer.83@web.de>
Signed-off-by: Tomas Cohen Arazi <tomascohen@theke.io>
Adds other title type based on ind2 value. ind2 overridden by $i value.
Signed-off-by: Indranil Das Gupta (L2C2 Technologies) <indradg@gmail.com>
Signed-off-by: Jonathan Druart <jonathan.druart@bugs.koha-community.org>
Signed-off-by: Tomas Cohen Arazi <tomascohen@unc.edu.ar>
Test plan:
1) Apply this patch
2) Ensure you are using the default XSLT setting for the staff and opac search results and record details
3) Find or create a record with MARC tags 100,110,111
4) Perform an opac search that would show the record in the search results.
5) Click title to review record.
6) Note the fields updates 100,110,111 to show subfields a,b,c,d,q and t.Multiple fields are separated by span class=separator |. Includes 100$j and handles multiple relator terms/codes.
7) Repeat steps 4 - 6 for the staff interface
Signed-off-by: Nick Clemens <nick@quecheelibrary.org>
Signed-off-by: Kyle M Hall <kyle@bywatersolutions.com>
Signed-off-by: Tomas Cohen Arazi <tomascohen@theke.io>
Test Plan:
1) Apply this patch
2) Ensure you are using the default XSLT setting for the staff and opac record details
3) Find or create a record with MARC tags 130/240/730
4) Perform an opac search that would show the record in the search results.
5) Click title to review record.
6) Fields show subfields a,d,f,g,h,k,l,m,n,o,p,r,s,t with multiple fields separated by span class=separator |
7) Repeat steps 4 - 6 for the staff interface
Signed-off-by: Nick Clemens <nick@quecheelibrary.org>
Signed-off-by: Kyle M Hall <kyle@bywatersolutions.com>
Signed-off-by: Tomas Cohen Arazi <tomascohen@unc.edu.ar>
Test Plan:
1) Apply this patch
2) Ensure you are using the default XSLT setting for the staff and opac search results and record details
3) Find or create a record with MARC tags 336,337,338
4) Perform an opac search that would show the record in the search results.
5) Click title to review record.
6) Adds fields 336, 337 and 338 to staff and opac details. Adds comma between multiple subfields and | with class='separator' between multiple datafields (e.g. two 336 fields)
7) Repeat steps 4 - 6 for the staff interface
Signed-off-by: Bernardo Gonzalez Kriegel <bgkriegel@gmail.com>
Works, no errors
Signed-off-by: Marcel de Rooy <m.de.rooy@rijksmuseum.nl>
Signed-off-by: Tomas Cohen Arazi <tomascohen@unc.edu.ar>
Display 773 in opac and staff details when ind1 !=1
Test plan
=========
1/ Add a new record which uses the 773 field to an instance running
master code. (the selected MARC framework should have the 773's
relevant sub-fields enabled and visible on staff client, opac and
the editor).
2/ Set ind1 as '0' (zero). The note should be displayed both on OPAC
as well as the staff client.
3/ Reset ind1 with a non-zero value or leave it blank. The display
note should no longer be visible from either client or opac.
4/ Apply the patch.
5/ Repeat step #1 and #2. The note is displayed on staff and opac.
6/ Repeat step #3. The display note should be visible on both staff
and opac.
7/ run koha-qa.pl -c 1 -v 2
Note : For #1 above, the following LoC record was used:
http://www.loc.gov/marc/bibliographic/examples.html#monographic
The patch applied cleanly and performed as expected.
The koha-qa.pl gave OK as results.
Signed-off-by: Indranil Das Gupta <indradg@gmail.com>
Signed-off-by: Kyle M Hall <kyle@bywatersolutions.com>
Signed-off-by: Tomas Cohen Arazi <tomascohen@unc.edu.ar>
Mulitple 082 fields are already separated by |, but multiple
$a in one 082 field were only separated by space, making those
not easy to read.
Patch takes care that the | separator is used in all cases.
To test:
- Catalog a record with multiple 082 fields
- Add one or multiple $a subfields to each
- Verify every single classification is separated from
the others with a | in staff and in OPAC detail pages
Signed-off-by: Nick Clemens <nick@quecheelibrary.org>
Signed-off-by: Jonathan Druart <jonathan.druart@koha-community.org>
Signed-off-by: Tomas Cohen Arazi <tomascohen@unc.edu.ar>
Test Plan:
1) Apply this patch
2) Ensure you are using the default XSLT setting for the staff and opac record details
3) Find or create a record with MARC tags 700,710,711
4) Perform an opac search that would show the record in the search results.
5) Click title to review record.
6) Note the fields updates 700,710,711 to show subfields a, b, c, d, e, f, g, h, i, k, l, m, n, o, p, r, s, t, u, x. Multiple fields are separated by span class=separator |. Adds Related and Contained Works as new headings.
7) Repeat steps 4 - 6 for the staff interface
Signed-off-by: Nick Clemens <nick@quecheelibrary.org>
Signed-off-by: Kyle M Hall <kyle@bywatersolutions.com>
Signed-off-by: Tomas Cohen Arazi <tomascohen@gmail.com>
First, it is strongly recommended to set the OPACBaseURL. But
this patch allows the inclusion of the protocol and not just
a site.
Next, C4/Auth now puts OPACBaseURL into the template parameters
regardless of OPAC or Staff clients. t/db_dependent/Auth.t was
tweaked to add a check for confirming that get_template_and_user
adds OPACBaseURL to both OPAC and Staff templates.
In the staff client, once the OPACBaseURL is set, you get a nice
OPAC View link when viewing a biblio's detail. It should reflect
the protocol used now.
Hard coded 'http://' strings were removed from the
sample_notices.sql files. This is what required also updating
the letters table in the updatedatabase.pl script.
The explanation text in the sysprefs.sql needed updating too to
reflect the inclusion of the protocol. And this was the other
update done in the updatedatabase.pl script. The opac.pref file
was similarly changed as well.
catalogue/detail.pl had no need to pass a custom OpacUrl value,
since C4/Auth passes the required OPACBaseURL, so it and the
corresponding template were modified.
Both the MARC21 and NORMARC intranet details files had 'http://'
hard coded in them. This was removed.
Both the bootstrap and prog theme opac-detail template had a
protocol parameter that was used. The logic for the parameter
was not removed, because it is used extensively in one template.
Perhaps it should be used to simplify the other. However, the
calculated current_url parameter had references to the protocol
removed, because of the changes to OPACBaseURL.
opac/opac-shareshelf.pl had a hard coded 'http://' which was
removed.
t/db_dependent/Auth_with_cas.t had 'http://' added to the value
set for OPACBaseURL.
In virtualshelves/sendshelf.pl explicit code which sent the
OPACBaseURL preference was removed, since C4/Auth sends it all
the time now.
C4::Context::set_preference was tweaked to ensure that
OPACBaseURL would always start with http.
t/db_dependent/Context.t was tweaked to specifically test this.
The Shibboleth authentication needs OPACBaseURL set, and that
it be https protocol. The _get_uri routine was tweaked to always
pass back https:// as the protocol on the OPACBaseURL.
t/Auth_with_shibboleth.t was tweaked to specifically test the
changes.
TEST PLAN
---------
This is not an easy patch to test. Difficulties include:
- configuring Koha to run under https
(tweaking apache2 isn't so hard, just tricky)
- configuring Koha to run OPAC and Staff with Plak
(since code with comments about plak were sliced out)
- configuring Koha to use CAS
(may be requires for the CAS test)
1) Apply patch
2) Make sure OPACBaseURL is set without the protocol included.
UPDATEDATABASE
3) back up your DB
4) ./installer/data/mysql/updatedatabase.pl
-- It should run without errors.
5) Look up the OPACBaseURL system preference in the staff
client
-- It should have http:// prepended.
6) Run the mysqlclient from your koha git directory
USE koha_library;
SELECT content FROM letter WHERE content LIKE "%<<OPACBaseURL>>%";
-- There should be no prepended http:// on the
<<OPACBaseURL>>.
7) restore your DB
8) Make sure OPACBaseURL is set with the protocol included,
preferably https.
-- Using https requires a bunch of apache2 tweaks.
AUTH
9) Call up staff client.
10) Call up OPAC.
-- C4/Auth.pm doesn't barf.
11) Call up Plack staff client
12) Call up Plack OPAC.
-- C4/Auth.pm doesn't barf.
13) prove -v t/db_dependent/Auth.t
CONTEXT
14) Home -> Koha administration -> Global System Preferences
-> OPAC
15) Modify and save OPACBaseURL to not have http:// or https://
on it.
-- It should be modified to include http://
16) Modify and save another system preference.
-- It should save normally
17) prove -v t/db_dependent/Context.t
CATALOGUE/DETAIL (tt & pl)
18) Confirm the OPACBaseURL is set
19) Navigate to any biblio details in the staff client
-- There should be a "OPAC view" link which has the
correct http:// or https:// in it.
SQL (sample notices and sysprefs)
20) Run the mysqlclient from your koha git directory
USE koha_library;
DELETE FROM letter;
source installer/data/mysql/de-DE/mandatory/sample_notices.sql;
SELECT content FROM letter WHERE content LIKE "%<<OPACBaseURL>>%";
DELETE FROM letter;
source installer/data/mysql/en/mandatory/sample_notices.sql;
SELECT content FROM letter WHERE content LIKE "%<<OPACBaseURL>>%";
DELETE FROM letter;
source installer/data/mysql/nb-NO/1-Obligatorisk/sample_notices.sql;
SELECT content FROM letter WHERE content LIKE "%<<OPACBaseURL>>%";
DELETE FROM letter;
source installer/data/mysql/es-ES/mandatory/sample_notices.sql;
SELECT content FROM letter WHERE content LIKE "%<<OPACBaseURL>>%";
DELETE FROM letter;
source installer/data/mysql/fr-FR/1-Obligatoire/sample_notices.sql;
SELECT content FROM letter WHERE content LIKE "%<<OPACBaseURL>>%";
DELETE FROM letter;
source installer/data/mysql/it-IT/necessari/notices.sql;
SELECT content FROM letter WHERE content LIKE "%<<OPACBaseURL>>%";
DELETE FROM letter;
source installer/data/mysql/pl-PL/mandatory/sample_notices.sql;
SELECT content FROM letter WHERE content LIKE "%<<OPACBaseURL>>%";
DELETE FROM letter;
source installer/data/mysql/ru-RU/mandatory/sample_notices.sql;
SELECT content FROM letter WHERE content LIKE "%<<OPACBaseURL>>%";
DELETE FROM letter;
source installer/data/mysql/uk-UA/mandatory/sample_notices.sql;
SELECT content FROM letter WHERE content LIKE "%<<OPACBaseURL>>%";
-- Each of the selects should should lines that have
<<OPACBaseURL>> starting them, but no hard-coded http://
DELETE FROM systempreferences;
source installer/data/mysql/sysprefs.sql;
SELECT * FROM systempreferences WHERE variable='OPACBaseURL';
-- The explanation should reflect the new explanation.
QUIT
21) restore your DB
22) Make sure OPACBaseURL is set with the protocol included,
preferably https.
-- Using https requires a bunch of apache2 tweaks.
SLIM2INTRANETDETAIL
23) Set 'XSLTDetailsDisplay' system preference to default.
24) Set 'marcflavour' system preference to MARC21.
25) View any biblio's details.
-- the URL beside 'OPAC View' should have the appropriate
http:// or https://
26) Set 'marcflavour' system preference to NORMARC.
27) View any biblio's details.
-- the URL beside 'OPAC View' should have the appropriate
http:// or https://
OPAC-DETAIL
28) Set 'opacthemes' to bootstrap.
29) Set 'SocialNetworks' to enabled.
30) In OPAC, view any biblio's details.
-- the Share links should have the appropriate protocol on
the OPACBaseURL.
31) Set 'opacthemes' to prog.
32) In OPAC, view any biblio's details.
-- the Share links should have the appropriate protocol on
the OPACBaseURL.
AUTH_WITH_CAS
33) prove -v t/db_dependent/Auth_with_cas.t
OPAC-SHARESHELF
34) Set 'OpacAllowSharingPrivateLists' to allow.
35) In OPAC, 'Save to Lists' a search result.
36) Save it to a new private list.
37) Click the Lists button, and select the new list.
38) Click the Share button.
AUTH_WITH_SHIBBOLETH
39) prove -v t/Auth_with_shibboleth.t
-- needs to be tests on Debian, because I can't get
the Test::DBIx::Class installed in Ubuntu. :(
Rebased again on kohadevbox...
Signed-off-by: Jonathan Druart <jonathan.druart@biblibre.com>
Signed-off-by: Bernardo Gonzalez Kriegel <bgkriegel@gmail.com>
Signed-off-by: Marcel de Rooy <m.de.rooy@rijksmuseum.nl>
Signed-off-by: Tomas Cohen Arazi <tomascohen@gmail.com>
This patch will resolve the issue of not being able to
search with parens in a subject heading by editing the xslt
To test:
* Apply patch
* Search Koha for a title with ( ) in the subject
* Click the subject
* Results should be returned
* Repeat in OPAC and Staff client
Signed-off-by: Nick <Nick@quechelibrary.org>
Signed-off-by: Katrin Fischer <Katrin.Fischer.83@web.de>
Signed-off-by: Tomas Cohen Arazi <tomascohen@gmail.com>
This patch updates the display of the title and statement of responsibility in the
XSLT display in the staff and OPAC.
Display includes subfields a,b,c,h,k,n,p,s
Subfield c is wrapped in a span class=title_resp_stmt for easy suppression via css.
Subfield h is wrapped in a span class=title_medium for easy suppression via css.
To test:
* Search the opac
* Click the title
* Make sure the fields display properly
* Repeat for a few more titles
* Repeat in the Staff Client
Signed-off-by: Nick Clemens <nick@quecheelibrary.org>
Signed-off-by: Kyle M Hall <kyle@bywatersolutions.com>
Signed-off-by: Tomas Cohen Arazi <tomascohen@gmail.com>
This patch adds field 508 to the XSLT display in the staff and OPAC view.
Display includes subfield a.
To test:
* Search the opac
* Click the title
* Make sure the fields display properly
* Repeat for a few more titles
* Repeat in the Staff Client
Signed-off-by: Nick Clemens <nick@quecheelibrary.org>
Signed-off-by: Marcel de Rooy <m.de.rooy@rijksmuseum.nl>
Adjusted commit message. Only subfield a is relevant here.
This patch adds a separator | to the full and brief displays in the staff and OPAC views.
Separator wrapped with span clas=separator |
To test:
* Search the opac
* Click the title
* Make sure the fields display properly
* Repeat for a few more titles
* Repeat in the Staff Client
http://bugs.koha-community.org/show_bug.cgi?id=13386
Signed-off-by: Nick Clemens <nick@quecheelibrary.org>
Signed-off-by: Kyle M Hall <kyle@bywatersolutions.com>
Signed-off-by: Tomas Cohen Arazi <tomascohen@gmail.com>
Test Plan:
1) Apply this patch
2) Ensure you are using the default XSLT setting for the staff and opac record details
3) Find or create a record with MARC tags 655
4) Perform an opac search and select records with 655 field that would show the record in the search results
5) Note this patch adds field 655 to display. Displays subfields a,v,x,y,z. uses a vertical bar to separate multiple titles. Vertical bar is wrapped in span class="separator" for easy suppression/customization of separator.
6) Repeat steps 4 and 5 for the staff interface
Signed-off-by: Nick Clemens <nick@quecheelibrary.org>
Signed-off-by: Kyle M Hall <kyle@bywatersolutions.com>
Signed-off-by: Tomas Cohen Arazi <tomascohen@gmail.com>
This patch field 655 to the full displays in the staff and OPAC views. Multiple 655 fields are separated with a span class=separator | .
To test:
* Search the opac for records with genre/field 655
* Click the title
* Make sure the fields display properly
* Repeat for a few more titles
* Repeat in the Staff Client
http://bugs.koha-community.org/show_bug.cgi?id=13433
Signed-off-by: Nick Clemens <nick@quecheelibrary.org>
Signed-off-by: Kyle M Hall <kyle@bywatersolutions.com>
Signed-off-by: Tomas Cohen Arazi <tomascohen@gmail.com>
http://bugs.koha-community.org/show_bug.cgi?id=13434
Signed-off-by: Nick Clemens <nick@quecheelibrary.org>
Signed-off-by: Kyle M Hall <kyle@bywatersolutions.com>
Signed-off-by: Tomas Cohen Arazi <tomascohen@gmail.com>
Patch will add DDC classifications, divided with | below the subjects
in the OPAC and staff detail pages.
To test:
- catalogue a record with one or mulitple 082$a subfields
- verify the classifications are displayed in OPAC and staff detail page
- Add following CSS to OpacUserCSS or IntranetUserCSS:
.results_summary.ddc {
display:none;
}
- Verify the DDC classifications are now no longer displayed
Signed-off-by: Frederic Demians <f.demians@tamil.fr>
Test plan ok. Repetions of $a subfield are separated by a space, which seems
correct. I'm not sure whether other subfield than $a should be displayed on
intranet. Whatever, this could be added later.
Signed-off-by: Kyle M Hall <kyle@bywatersolutions.com>
Signed-off-by: Tomas Cohen Arazi <tomascohen@gmail.com>
Currently, 020$z (and 010$z fr UNIMARC) occurences are not shown, but the XSLT logic
used introduces punctuation characters for those $z occurences.
This patch adds a check for the existence of subfield a, and only loops
on $a subfields.
To test:
- Create/have a record with 020$z (or 010$z on UNIMARC) but no 020$a (no 010$a on UNIMARC).
- Open the detail page for the record (on both OPAC and staff).
=> FAIL: the ISBN label and ';' and '.' characters incorrectly shown.
- Repeat mixing with 020$a occurences to notice the bug.
- Apply the patch, reload
=> SUCCES: ISBN label shows only on the presence of a $a, and $z are skipped.
no matter how many ISBN fields you add.
- Sign off :-D
Regards
To+
http://bugs.koha-community.org/show_bug.cgi?id=12901
Signed-off-by: Nicole C. Engard <nengard@bywatersolutions.com>
Signed-off-by: Katrin Fischer <katrin.fischer.83@web.de>
Signed-off-by: Tomas Cohen Arazi <tomascohen@gmail.com>
Currently, 022$z (and 011$z for UNIMARC) occurences are not shown, but the XSLT
logic used introduces punctuation characters for those $z occurences.
This patch adds a check for the existence of subfield a, and only loops
on $a subfields.
To test:
- Create/have a record with 022$z (or 011$z on UNIMARC) but no 022$a (no 011$a on UNIMARC).
- Open the detail page for the record (on both OPAC and staff).
=> FAIL: the ISSN label and ';' and '.' characters incorrectly shown.
- Repeat mixing with 022$a occurences to notice the bug.
- Apply the patch, reload
=> SUCCES: ISSN label shows only on the presence of a $a, and $z are skipped.
no matter how many ISSN fields you add.
- Sign off :-D
Regards
To+
Signed-off-by: Frederic Demians <f.demians@tamil.fr>
Works as described on an UNIMARC DB. Mimics what's done for ISBN field.
Signed-off-by: Kyle M Hall <kyle@bywatersolutions.com>
Signed-off-by: Tomas Cohen Arazi <tomascohen@gmail.com>
As bugs 12724 and 12726 did on OPAC, this patch adds similar changes to
Intranet Results and Details XSLT view. It shows information from tag 264 on
the Publisher line of Intranet Results and Detail.
Test plan (see also bug 12742 and the rules mentioned there):
[1] Add tag 260 and some 264s to your MARC21 record.
[2] Check the display of Intranet Results.
[3] Check the display of Intranet Detail.
Signed-off-by: Bernardo Gonzalez Kriegel <bgkriegel@gmail.com>
Results and detail show 264. I added 2 but only shows the second,
is that right?
[Reply from marcel:] Yes. Based on the rules described, it picks the most
'appropriate' 264.
Signed-off-by: Brendan Gallagher <brendan@bywatersolutions.com>
Signed-off-by: Tomas Cohen Arazi <tomascohen@gmail.com>
Currently, 710$a and $b and $b will not display correctly.
This patch tries to improve the display adding the missing
space between both subfields.
Please test.
Signed-off-by: Bernardo Gonzalez Kriegel <bgkriegel@gmail.com>
Tested, work as described on staff & opac for 710 detailed view.
Add space and punctuation.
No errors.
Signed-off-by: Marcel de Rooy <m.de.rooy@rijksmuseum.nl>
Signed-off-by: Tomas Cohen Arazi <tomascohen@gmail.com>
The label Material type better describes what the icon presents.
It is based on leader values of the MARC record.
Revised Test Plan
-----------------
1) Set the Staff system preference XSLTDetailsDisplay to
'default' and save.
2) Set the Staff system preference XSLTResultsDisplay to
'default' and save.
3) Click 'Search the catalog' tab in the search area.
4) Search for something
5) Look for a biblio that has 942$c set to some type.
-- It should display "Type:"
Or take a result and modify it to have a 942$c.
6) Look at the biblio details
-- It should also display "Type:"
7) Apply the patch
8) Search for the same biblio again.
-- It should display "Material type:" this time.
9) Look at the biblio details
-- It should display "Material type:" this time.
10) Run the koha qa test tool.
Signed-off-by: Mark Tompsett <mtompset@hotmail.com>
Note: This is a simple string substitution.
Signed-off-by: Katrin Fischer <Katrin.Fischer.83@web.de>
Signed-off-by: Galen Charlton <gmc@esilibrary.com>
This patch adds the ti,phr index to the search queries for the 780
and 785 MARC fields in the XSLT templates.
Test Plan:
1) Use a record with 780 and 785 MARC fields with data in the "a" or
"t" subfields. (You might need to add these fields to an existing
record, or create a new record. You might also need to change your
MARC Bibliographic Framework settings to not "hide" these fields in
your framework(s)).
N.B. The data in the "a" or "t" subfields should be a title that
exists in your database. Otherwise, this test might seem misleading.
2) Set the system preferences "XSLTDetailsDisplay" and
"OPACXSLTDetailsDisplay" to "default".
3) Go to your record (which contains the 780/785 fields), and look
for links with linktext derived from the "a" or "t" fields in the
record. These may or may not be prefaced with labels such as
"Continued by" or "Continues".
4) Note that the links are formatted "q=TITLE". Click this link
and note the possibly high number of results.
5) APPLY THE PATCH
6) Shift+Refresh your record page, and observe that the link should
now say "q=ti,phr:TITLE". Click this link and note that you are
either taken directly to the referenced article or that your
search results are considerably fewer.
Signed-off-by: Chris Cormack <chris@bigballofwax.co.nz>
Signed-off-by: Katrin Fischer <Katrin.Fischer.83@web.de>
XSLT change only, no regressions found.
Signed-off-by: Galen Charlton <gmc@esilibrary.com>
Prior to this patch, if a 100/700 had a $c, it would be
displayed with no space between the contents of $a and $c in XSLT mode.
For example,
100 1#$aSeuss,$cDr.
would be displayed as
SeussDr
The problem was caused by the original version of the stylesheets
drawing a bit too much from the MARC21 to MODS transformation.
To test:
[1] In a MARC21 database, turn on XSLT display mode for
staff and OPAC.
[2] Create or identify a bib that has a 100 or 700 field
with both a $a and a $c.
[3] Before applying the patch, verify that the name is
displayed in bib details and search results with the
name and title squashed together. For example, "SeussDr"
[3] After applying the patch, verify that the name displays
in bib details and search results with a space and
intervening punctuation between the name and the title. For
example, "Seuss, Dr."
Signed-off-by: Galen Charlton <gmc@esilibrary.com>
Signed-off-by: Jared Camins-Esakov <jcamins@cpbibliography.com>
Signed-off-by: Katrin Fischer <Katrin.Fischer.83@web.de>
Passes test plan, works nicely.
Signed-off-by: Galen Charlton <gmc@esilibrary.com>
As in Bug 6278, this patch replace ">at<" with ">a_t<"
so not to mislead translators. Found more cases that
initial description.
To test:
1) Check that problem exists and only on xslt files,
using your preferred language
egrep -B10 "^msgid \"at\"" misc/translator/po/xx-YY-i-staff-t*
2) Apply the patch
3) Update translation file
(cd misc/translator; perl translate update xx-YY)
4) Verify the problem is gone, repeat 1
5) If you like verify new entries in PO file
egrep -B15 "^msgid \"a_t\"" misc/translator/po/xx-YY-i-staff-t*
Signed-off-by: Marcel de Rooy <m.de.rooy@rijksmuseum.nl>
Tested this with field 780 and running a Dutch translation.
Signed-off-by: Jared Camins-Esakov <jcamins@cpbibliography.com>
Signed-off-by: Galen Charlton <gmc@esilibrary.com>
To test:
- Check OPAC and intranet XSLT view for a record that contains
780 and 785 fields.
- Verify there is no space between the label and the content of the
field.
- Apply patch.
- Verify the display both in intranet and OPAC is a little nicer now.
Signed-off-by: Galen Charlton <gmc@esilibrary.com>
Signed-off-by: Chris Cormack <chris@bigballofwax.co.nz>
Signed-off-by: Galen Charlton <gmc@esilibrary.com>
Implements the material type icons shown in the MARC21 XSLT result list
of the OPAC for the intrant result list.
Also adds the system preference DisplayIconsXSLT as an intranet analogue
for the OPAC system preference DisplayOPACiconsXSLT and corrects the
descriptions of both preferences in the syspref editor.
To test:
0) Run database update to add new system preference
1) Activate default XSLTResultsDisplay
2) Check the new system preference DisplayIconsXSLT shows up correctly
and is activated by default. Compare descriptions between DisplayIconsXSLT
and DisplayOPACiconsXSLT.
3) Check the intranet result list for icons showing up after 'Type:' and
before the corresponding description. Detail pages should be showing
the 'Type:' as before.
4) Turn off DisplayIconsXSLT.
5) Check the line containing 'Type:', format and audience information is now
hidden from the result list.
6) Check that the 'Type:'line is also hidden from the detail page.
Signed-off-by: Owen Leonard <oleonard@myacpl.org>
Signed-off-by: Paul Poulain <paul.poulain@biblibre.com>
Signed-off-by: Jared Camins-Esakov <jcamins@cpbibliography.com>
Shows dissertation note in OPAC and intranet detail pages.
To test:
1) Look at records with and without 502 in intranet and OPAC
2) Verify display is correct and consistent
Signed-off-by: Nicole C. Engard <nengard@bywatersolutions.com>
All tests pass in staff and opac
Signed-off-by: Marcel de Rooy <m.de.rooy@rijksmuseum.nl>
Signed-off-by: Jared Camins-Esakov <jcamins@cpbibliography.com>
Fixes spelling to follow capitalization rules in OPAC and intranet MARC21
detail pages.
Signed-off-by: Nicole C. Engard <nengard@bywatersolutions.com>
Changes all look good.
Signed-off-by: Marcel de Rooy <m.de.rooy@rijksmuseum.nl>
Signed-off-by: Jared Camins-Esakov <jcamins@cpbibliography.com>